Parameter
Factory Model Number | FLM-AHP-002HC410 | FLM-AHP-003HC410 | FLM-AHP-005HC410S | FLM-AHP-006HC410S | FLM-AH-008HC410S | FLM-AH-010HC410S | ||
Heating Capacity Range | kW | 2.5-10 | 4-13 | 7-17 | 7-20 | 10-27 | 13-34 | |
Heating (7/6℃,30/35℃) | Heating Capacity | kW | 8.3 | 10.9 | 16.1 | 18.5 | 25.3 | 31.8 |
Power Input | kW | 1.99 | 2.63 | 3.89 | 4.38 | 5.91 | 7.63 | |
COP | W/W | 4.17 | 4.15 | 4.13 | 4.22 | 4.28 | 4.17 | |
Heating (7/6℃,40/45℃) | Heating Capacity | kW | 7.85 | 10.3 | 14.5 | 16.7 | 24.9 | 31.0 |
Power Input | kW | 2.32 | 3.07 | 4.47 | 5.09 | 7.18 | 9.06 | |
COP | W/W | 3.38 | 3.35 | 3.24 | 3.28 | 3.47 | 3.42 | |
Heating (-15/-16℃,30/35℃) | Heating Capacity | kW | 5.16 | 6.82 | 9.7 | 11 | 15.23 | 19.15 |
Power Input | kW | 2.11 | 2.71 | 3.79 | 4.25 | 6.24 | 7.78 | |
COP | W/W | 2.45 | 2.51 | 2.56 | 2.59 | 2.44 | 2.46 | |
Cooling (35/24℃,23/18℃) | Heating Capacity | kW | 7.91 | 10.4 | 15.6 | 18.1 | 24.5 | 30.7 |
Power Input | kW | 2.35 | 3.01 | 4.71 | 5.36 | 6.96 | 8.84 | |
COP | W/W | 3.37 | 3.45 | 3.31 | 3.38 | 3.52 | 3.47 | |
Electrical power supply | V/Ph/Hz | 230/1/50 | 230/1/50 | 380/3/50 | 380/3/50 | 380/3/50 | 380/3/50 | |
Gas line | Inches | 5/8 | 5/8 | 3/4 | 3/4 | 3/4 | 1 | |
Liquid line | Inches | 3/8 | 3/8 | 3/8 | 3/8 | 3/8 | 1/2 | |
Compressor type | / | Rotary | Rotary | Rotary | Rotary | Rotary | Rotary | |
Compressor brand | / | Panasonic | Panasonic | Panasonic | Panasonic | Panasonic | Panasonic | |
Refrigerant type | / | R410A | ||||||
Refrigerant load | Kg | 2.1 | 2.7 | 3.7 | 4.1 | 5.2 | 6.5 | |
Air conditioning maximum pressure | Bar | 3 | ||||||
Air conditioning expansion tank volume | Litres | 5 | ||||||
Air conditioning water connection | Inches | 1 | 1.2 | 1.5 | ||||
Dimensions | Indoor unit | mm(HxWxL) | 720x435x353 | |||||
Outdoor unit | mm(HxWxL) | 1030/380/812 | 1030/380/812 | 1030x380x1342 | 1030x380x1342 | 1161x476x1550 | 1161x476x1550 | |
Packaged Dimensions | Indoor unit | mm(HxWxL) | 830x530x450 | |||||
Outdoor unit | mm(HxWxL) | 1155/500/960 | 1155/500/960 | 1155x500x1500 | 1155x500x1500 | 1220x550x1650 | 1440/550/2070 | |
Net weight | Indoor unit | Kg | 50 | 52 | 55 | 60 | 68 | 76 |
Outdoor unit | Kg | 70 | 75 | 120 | 128 | 160 | 195 | |
Packaged weight | Indoor unit | Kg | 55 | 57 | 63 | 68 | 76 | 84 |
Outdoor unit | Kg | 80 | 85 | 130 | 138 | 175 | 215 | |
Noise level | Indoor unit | dB(A) | 30 | |||||
Outdoor unit | dB(A) | 50 | 53 | 55 | 55 | 57 | 59 | |
Maximum pipe length | m | 50 | ||||||
Maximum height difference | m | 30 |
Product Advantages
R410A 27kw Split DC Inverter Heat Pump - 2024 Heat Pump Water Heater Technology Exploration
With the continuous progress of science and technology, heat pump technology plays an increasingly important role in the field of cooling, heating and hot water supply.R410A 27kw Split DC Inverter Heat Pump, as an outstanding representative of advanced inverter air source heat pump technology, will bring you a more efficient and environmentally friendly experience of energy utilisation.
Firstly, let's understand the working principle of the split DC inverter air source heat pump. The heat pump uses the air in the environment as the heat source, and regulates the running speed of the compressor through inverter technology to precisely control the cooling and heating effect according to the actual demand. Compared with traditional fixed-speed compressors, inverter technology enables the heat pump to regulate energy consumption more intelligently, improving the energy efficiency ratio, reducing energy consumption and saving costs for users.
The 27kw cooling/heating capacity is sufficient to meet the needs of medium to large buildings, providing a comfortable indoor environment. And in 2024, heat pump technology has also made a new breakthrough in the field of hot water supply. As an extended application of heat pumps, heat pump water heaters have become an increasingly popular choice. By utilising the heating principle of heat pumps, heat pump water heaters are able to efficiently convert the heat energy in the environment into hot water, providing users with a stable and continuous supply of hot water, which not only ensures the comfort of hot water, but also reduces energy consumption and operating costs, contributing to environmental protection.
Energy efficiency:
Due to the separation of indoor and outdoor components, split heat pumps can often achieve higher efficiency levels than integral heat pumps. Full DC inverter technology combined with Panasonic compressors ensures high energy efficiency, optimizing performance and saving energy.
Precise temperature control:
DC inverter technology enables precise temperature control, maintaining consistent comfort while minimizing energy waste.
Quiet operation:
With a Panasonic compressor, operation is smooth and quiet, improving user comfort and reducing noise levels.
Reduce heat loss:
A split heat pump can minimize heat loss in the refrigerant lines between the indoor and outdoor units, potentially increasing overall system efficiency.
Versatility:
Suitable for a wide range of applications from residential to commercial environments, providing efficient heating and cooling solutions.
Long service life:
The use of high-quality components, including Panasonic compressors, ensures durability and longer service life, reducing maintenance requirements and costs.
WIFI smart control options:
Provides wifi smart control functionality, allowing users to remotely monitor and adjust the heat pump for enhanced convenience and energy optimization.
Installation Flexibility:
Split heat pumps feature separate indoor and outdoor units connected by refrigerant lines, providing installation flexibility. This allows for more placement options, such as installing the outdoor unit in a less conspicuous or quieter location.
Scalability:
Split heat pump systems can be more easily expanded to meet the specific heating and cooling needs of different spaces by adding additional indoor units to a single outdoor unit, providing greater flexibility in system design.
Zone Control:
Split heat pumps can support zone control by connecting multiple indoor units to a single outdoor unit, allowing for individual temperature control in different areas of the building.
Application
Multilingual control panel
Connection diagram
Split heat pump installation is a critical step in ensuring proper operation and maximising the performance of your heat pump system.R410A 27kw Split DC Inverter Heat Pumps, as energy efficient state-of-the-art equipment, their correct installation is essential to provide a comfortable indoor environment. Below is a detailed guide to the installation of a split heat pump:
Site selection: firstly, choose a suitable site for installing the heat pump. Outdoor units are usually installed on well-ventilated, solid ground, away from noise sources and direct sunlight. The indoor unit is usually installed on the wall of the indoor space, and the location should be chosen to be at a certain height from the floor to allow air circulation and to enable easy connection of pipework.
Preparation: Before installation, ensure that all relevant tools and materials are available. Mark the installation location and determine the path for piping connections according to the installation instructions and schematic diagrams provided by the manufacturer.
Outdoor unit installation: Install the outdoor unit in the pre-prepared position and make sure it is flush and stable with the ground. Connect the power supply and piping according to the installation manual, taking care to avoid excessive bending or stretching of the piping to ensure smooth operation of the system.
In summary, proper split heat pump installation is key to ensuring efficient system operation and optimal performance. Following the installation guidelines above and seeking professional help when needed will help you achieve a stable, comfortable indoor environment.
keywords: inverter air source heat pump,split system heat pump,2024 heat pump water heater,heat pump 30kw,mini split heat pump,inverter air source heat pump,split system heat pump,2024 heat pump water heater,heat pump 30kw,mini split heat pump,inverter air source heat pump,split system heat pump,2024 heat pump water heater,heat pump 30kw,mini split heat pump,inverter air source heat pump,split system heat pump,2024 heat pump water heater,heat pump 30kw,mini split heat pump,inverter air source heat pump,split system heat pump,2024 heat pump water heater,heat pump 30kw,mini split heat pump,heat pump 30kw,heat pump 30kw,heat pump 30kw